Before you start
A hearing loop (audio induction loop) sends sound directly to hearing aids and cochlear implants as a magnetic field. The listener switches their hearing aid to the T (telecoil) setting and hears the microphone or programme sound clearly, without the room's echo and background noise. For many people with hearing loss, the difference between a room with a working loop and one without is the difference between following a meeting, service or performance and missing it.
Under the Equality Act 2010, service providers must make reasonable adjustments for disabled people, and a hearing loop is often one of them at reception desks, ticket counters, meeting rooms, places of worship, theatres and lecture rooms. A loop that does not work, or a loop sign where there is no working loop, helps nobody. This guide covers how loops work, the main types, how to feed and set them up, the performance standard, testing and maintenance.
Large and complex loop systems should be designed and commissioned by a specialist, often with software modelling. This guide gives you the knowledge to plan, specify, check and look after a loop, and to set up simple systems such as counter loops and small rooms.
How a hearing loop works
A loop amplifier drives an audio current through a cable laid around, under or over the listening area. The current creates a magnetic field that follows the sound. A small coil in the hearing aid (the telecoil) picks up the field and turns it back into sound. Because the hearing aid takes the sound straight from the loop, the listener hears the microphone as if it were in their ear, at a level they control with their hearing aid.
Loop amplifiers are current drive amplifiers: they control the current in the cable, not the voltage, because the current sets the field strength. They must be matched to the loop's resistance and length, and they are not interchangeable with ordinary audio amplifiers.
Types of loop
| Type | Where it is used | Things to know |
|---|---|---|
| Counter loop | Reception desks, ticket and bank counters, pharmacies, help points | A small loop pad or cable under the counter, with its own microphone facing the staff member. Covers the customer's position only, about a metre. |
| Portable loop | Meeting rooms, one-to-one conversations, temporary use | A battery unit with a built-in microphone and a small loop pad or neck loop. |
| Perimeter loop | Small and medium rooms without much metal in the structure | One turn of cable around the edge of the room. Simple and economical, but the field spills well outside the room, and metal in floors and ceilings weakens it. |
| Cancellation and figure-of-eight loops | Rooms next to another looped room | Arrangements that reduce spill in one direction. |
| Phased array (low spill) | Large rooms, buildings with metal structures, side-by-side rooms, confidential spaces | Two interleaved grids of cable driven by two amplifier channels. Even coverage, much less spill and much better in buildings with steel. Needs specialist design. |
| Neck loop | Individual use with a personal amplifier or receiver | A loop worn around the neck, plugged into a personal receiver (for example from an infrared or radio assisted listening system). |
Things that affect a loop
- Metal loss. Steel in floors, ceilings, walls and furniture absorbs the magnetic field, especially at high frequencies, making speech sound dull and weak. Survey the building before choosing the loop type: phased arrays and metal loss compensation in the amplifier deal with it far better than more power.
- Overspill. The field from a perimeter loop extends a long way beyond the cable, into neighbouring rooms and the floors above and below. Two perimeter loops close together interfere with each other. Where rooms are next to each other, or conversations are confidential, use low-spill designs.
- Background magnetic noise. Mains wiring, transformers, lighting, lifts and some electronic equipment create magnetic hum that the hearing aid hears too. Measure it before installing: if it is too high, the loop will sound noisy whatever you do.
- Listening height. The field is strongest and most even a little away from the plane of the cable. Never run loop cable at ear height: install it in or under the floor, or at ceiling level, well above or below the listeners' heads.
The performance standard
Loop systems are specified, installed and tested to BS EN IEC 60118-4. Its main requirements, measured at the listening height across the whole area of use, are:
| Requirement | Target | What it means |
|---|---|---|
| Field strength | 400 mA/m (0 dB), within ±3 dB | The reference level for speech peaks, measured at 1 kHz. All hearing aids are designed around it. |
| Field strength variation | Within ±3 dB across the area of use | Listeners should not hear the level change as they move or sit in different seats. |
| Frequency response | Within ±3 dB from 100 Hz to 5 kHz, relative to 1 kHz | Speech stays clear and natural. Metal loss usually shows up as a fall at high frequencies. |
| Background noise | Low enough not to be heard: no worse than −32 dB(A) relative to the reference, and ideally −47 dB(A) or better | Measured with the loop off. Magnetic hum from building services. |
Measurements are made with a field strength meter at the height of the listeners' heads (about 1.2 m seated or 1.7 m standing), not with a simple loop listener.
Feed the loop
A loop is only as good as the sound you put into it.
- Use the sound system's mixed output, such as a matrix or post-fade auxiliary output, so the loop gets every microphone that the room hears, plus video playback, video calls and music.
- Keep it dry. Leave out reverb and other effects, which make speech harder to follow through a hearing aid.
- Do not delay it. Loop listeners also see the speaker's lips; adding delay spoils lip reading.
- Use the loop amplifier's automatic gain control (AGC) or compressor, so quiet and loud speakers both arrive at a steady level close to the reference.
- Check the microphones. If the presenter is not on a microphone, they are not in the loop. Always use the microphones, even in a small room where people "can hear fine".
- Counter loops have their own microphone, which should face the staff member and sit close to them, not the customer.
Install and commission
- Survey the site. Measure background magnetic noise with the loop off and everything else on. Check for metal in the structure using a temporary test loop and a field strength meter, and identify neighbouring rooms that could be affected by spill.
- Choose the design: counter loop, perimeter, or phased array, with the cable size and route to suit the amplifier.
- Route the cable under the floor finish, in a floor chase, under carpet, or at ceiling level, away from ear height. Use flat copper tape under carpet and suitable cable in screed. Keep loop cables at least about 60 cm from parallel data, audio and mains cables, and cross them at right angles.
- Twist the feed cables between the amplifier and the loop so they do not create a field of their own.
- Connect and check the loop resistance against the amplifier's specified range.
- Set the level using the amplifier's 1 kHz test tone (or pink noise) and a field strength meter, adjusting the drive until the field is 400 mA/m in the middle of the area.
- Check coverage across the area at listening height, and the frequency response at 100 Hz, 1 kHz and 5 kHz. Use the amplifier's metal loss compensation to restore the high frequencies if needed.
- Check with real programme: speech from the room's microphones, listened to on a loop listener, at different positions.
- Record the results on a commissioning certificate, with the meter readings and a plan of the measurement positions, and hand it to the building owner.
Signs, staff and users
- Display the hearing loop sign (the ear with a T) at the entrance to the looped area and at the counter, only where the loop works.
- Mark the area covered if the loop does not cover the whole room, such as reserved seating in a theatre.
- Train staff to switch the loop on (if it is not permanently on), check it with a listener, use the counter microphone, and speak normally towards it.
- Tell people about it: on your website, in event information and at the start of events.
Testing and maintenance
- Daily or before each event: check the amplifier is on and its indicators are normal, then listen with a loop listener while someone speaks into the microphone.
- Regularly (for example monthly): walk the area with the listener, checking for dead spots, noise and distortion.
- Annually, or after building works or changes: have the system tested with a field strength meter against the standard, and keep the certificate.
- After building work, check the cable has not been cut or damaged and the amplifier settings have not changed.
- Keep a log of checks, faults and repairs.
Troubleshooting
| Problem | Likely causes | Things to try |
|---|---|---|
| No sound in the loop | Amplifier off, no input signal, loop cable broken or disconnected | Check the amplifier's power, input and loop indicators, check the input feed, and measure the loop resistance for continuity. |
| Hum or buzz | Background magnetic noise, mains interference on the audio feed | Listen with the loop amplifier off: if the hum stays, it is magnetic noise from the building. If it stops, check the audio feed for ground loops. |
| Sound weak or dull | Level set too low, metal loss, presenter not using the microphone | Re-check the field strength, apply metal loss compensation, and make sure microphones are used. |
| Uneven coverage | Perimeter loop too large for the room, metal in the structure | Consider a phased array design or splitting the area. |
| Loop heard in the next room | Overspill from a perimeter loop | Use a low-spill design, cancellation loops or a different layout. |
| Distortion on loud speech | Input overloaded, amplifier clipping | Lower the input level and check the AGC settings. |
| Users say it does not work | Hearing aid not set to T, or no telecoil programme fitted | Check the loop works with a listener; the user may need their audiologist to enable the telecoil setting. |